Coordinate warehouse electrical and fire inspection preparation Plan around goods movement, restricted areas, access height and operational dependencies. Plan around goods movement, restricted areas, access height and operational dependencies. Identify which electrical and fire services are commissioned, coordinate their access requirements and agree any disruption with site operations. Keep each service’s scope and evidence separate. A combined visit can simplify coordination, but it does not make one inspection cover every warehouse safety obligation. Warehouse preparation starts with the movement of people and stock. A board that was accessible last month may now be behind racking or temporary storage, while an inspection route may cross a live loading area. Electrical and fire services can share some planning information, but they still need their own scope. This guide helps site managers organise that shared preparation. It is sector planning guidance, not a description of warehouse projects undertaken by Reaction Group. The relevant government warehouse fire guidance cited here applies to England; confirm the correct fire safety framework for premises in other UK jurisdictions. Treat access as an operational task Walk the intended access route with someone who understands warehouse operations. Identify vehicle routes, loading times, segregated pedestrian access and temporary stock areas. Arrange clearance through the authorised warehouse team rather than expecting an inspection engineer to move goods or equipment. HSE guidance on managing contractors around workplace transport supports agreeing the relevant safety arrangements in advance. A route plan should explain how the inspection team reaches the work area safely, including when operations change during the visit. Describe unusual areas before appointment Tell the supplier about high-level equipment, restricted plant areas and any specialist environment relevant to the scope. Confirm what access equipment is needed and who provides it. Reaction Group’s terms describe standard access limitations and separate arrangements for specialist access; use the quotation to resolve the actual requirement. If charging areas, automated systems or other specialist installations are involved, identify them specifically. Do not assume that a general warehouse description gives an inspector enough information to define their boundaries. Movement | Identify vehicle routes and safe inspection-team access. | A current route briefing from operations. Clearance | Arrange authorised removal of stock from agreed work areas. | A clearance owner and readiness confirmation. Height | Describe equipment beyond ordinary access arrangements. | An agreed specialist access provision. Service boundary | Specify which installations and fire services are commissioned. | Separate scopes linked to a common site plan. Operational dependencies | Identify equipment or areas that cannot be interrupted without approval. | Named release authority and approved windows. Coordinate services without merging their evidence An EICR, fire risk assessment, emergency lighting inspection and fire door inspection answer different questions. Share the site plan, contacts and access arrangements, then ask each service what else it requires. Agree how any temporary impairment or alarm-related activity is controlled by the site. Avoid overlapping work that removes the same access route or requires incompatible operational conditions. A coordinated schedule should make the dependencies visible without converting several specialist records into a vague “site passed” statement. Recheck temporary storage shortly before the inspection date. Coordinate access equipment with the people controlling vehicle and pedestrian movement. Make unusual charging, automated or specialist areas visible during scoping. Keep electrical and fire findings linked to their own reports and action owners. Clearing stock for one team blocks the other team’s route A hypothetical warehouse schedules an EICR and fire door inspection on the same morning. Operations plans to clear the electrical room by staging goods in a corridor the door inspector needs to use. Each service appears ready when considered separately. Put the proposed routes and temporary storage arrangements on one site plan. The warehouse supervisor can arrange a safe clearance location and agree when each area is released, while the specialists confirm their own requirements. Vehicle movements and pedestrian access should remain under the site’s normal controls. Give the shift supervisor the sequence rather than leaving it in a planning email chain. If the teams cannot use the areas safely together, change the schedule. The purpose of coordination is workable access and meaningful evidence from each service, not simply two attendance entries against the same date. Use findings to improve the next visit After attendance, review blocked access and repeated restrictions as planning information. A limitation caused by stock storage may require a different clearance process before a return visit. A fire risk finding about storage or escape routes belongs in the appropriate fire action process, even if it was noticed during a coordinated programme. Keep separate observation references and owners. Update the site pack with useful access knowledge so the next visit begins with an improved instruction rather than the same unresolved uncertainty.